Home » Product List » H/L Voltage Clamp Meter » H/L Voltage Clamp Meter (ETCR9000)
Product Details
H/L Voltage Clamp Meter (ETCR9000)
| Packing: | Aluminumfoil |
|---|---|
| Model NO.: | ETCR9000 |
| Standard: | CE |
| Unit Price/Payment: | FOBGuangZhou &257.40 |
| Trademark: | ETCR |
| Origin: | China |
| Min. Order: | 10pcs |
Model: ETCR9000
Category: H/L Voltage Clamp Meter
Measuring range: 10A/600A, second-range manual switch, automatic switch in all ranges
Illustration:
ETCR9000 Series H/L Voltage Clamp Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp meter with a high-voltage insulation rod, as to ETCR9000A type -- infrared transmission of test data, also equipped with receivers, which can monitor the tested data in a long distance on real-time. If not using an insulation rod, it can be also used as a high precision low-voltage clamp meter, or an alternating current meter, which can accurately measure 1mA of current or leakage current
| Function | High voltage AC current measurement, low voltage AC current, leakage current measurement, on-line AC current supervision. |
| Battery supply | DC6V alkaline dry battery (AAA*4) |
| Test mode | Clip –on CT,ntegral mode |
| Display dimensions | 4 digital LCD display, backlight function, suitable for dark place. |
| LCD dimensions | 47mm*28.5mm |
| Dimensions | Width *height* thickness:76mm*255mm*31mm |
| Clamp mouth | φ48mm |
| Sampling Rate | Twice per second |
| Measuring Scope | 0.1mA~1000A(50/60Hz automatic) |
| Resolution | 0.1mA |
| Measuring accuracy ( 23 ºC ± 5 ºC , 80%RH below ) | 0.1mA~299mA: ±1%±3dgt 300mA~49.9A: ±1.5%±5dgt 50.0A~199.9A: ±2%±5dgt 200A~600A: ±3%±5dgt 601A~1000A: ±4%±5dgt |
| Circuit Voltage | Test for the circuit below 23KV (operated with insulation rod) |
| Data memory | 99 Groups, during storage, the symbol "EM "gives indication, " FULL " mark will flash to indicate the memory has been full. |
| Peak Maintenance | The function of automatic capture and maintain the maximum average value, under general test mode, press HOLD button longer till PEAK light is bright, that is, start PEAK test function, also known as peak test. |
| Data Preservation | Under general test mode, press HOLD button to preserve data, "OLD " symbol display. |
| Data look out | "R"ymbol means turn up and down to look out the data is allow. |
| Overflow display | Outrange overflow display:isplayed by "L A"symbol |
| Auto Shut Down | In about 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption. |
| Battery voltage | When battery voltage reduced to 5V, battery low voltage symbol will filker to remind replacing battery |
| Meter quality | Tester: About 335g (Including battery), total quality of meter: about 2.5Kg (including insulation rod and battery.) |
| Working temperature and humidity | -10ºC~40ºC ; 80%Rh below |
| Storage temperature and humidity | -10ºC~60ºC;70%Rh below |
| Insulating bar dimensions | φ32mm,1m/ Section( Sections) |
| Insulation strength | AC 40KV/rms (Between insulation rod and clamp core) |
| Structure | Anti-Dripping Type II |
Inquiry Basket (